  • 4.1(2).jpg

1E low smoke halogen free flame retardant compensation cable for 300/500v nuclear power plant

Scopeofapplication  Thisproductissuitablefortheconnectionofnuclearpowerstationthermocouple,recorder,computeranddataprocessingsystem.  Cableconductorallowsthelong-termworkingtemperatureis90℃,shortcircu

Classification:

Nuclear power station Class 1E cable


Description

Scope of application

  This product is suitable for the connection of nuclear power station thermocouple, recorder, computer and data processing system.

  Cable conductor allows the long-term working temperature is 90 ℃, short circuit when the cable conductor does not exceed 250 ℃, the highest temperature duration of not more than 5 seconds.

  When environment temperature is lower than 0 ℃ when cable laying should be preheated.

  Plant reactor outside ambient temperature: a 10 ℃ to 55 ℃. Reactor in ambient temperature of the plant: 0 ℃, 60 ℃.

  Maximum relative humidity :100%, atmospheric pressure :0.086 to 0.106MPa.

  The cumulative dose of radiation under normal operating conditions in the reactor building is 25Mrad and the cumulative dose under accident operating conditions is 60Mrad.

Cable structure

Model and name

 

Model Security category name some Nominal cross section
HBKXEJGP K1  Ii-grade nickel-chromium alloy (positive pole) - nickel-silicon alloy (negative pole) conductor ethylene - propylene insulated copper wire braid total shield thermosetting sheath low smoke halogen free 1~61 1.0mm²
HBKCBEJGP The nuclear power plant USES lE grade copper (anode) - copper nickel alloy (cathode) conductor ethylene - propylene insulation copper wire braid total shield thermosetting sheath low smoke halogen free flame retardant thermocouple
HBKXYJYGP K3 Ii-grade nickel-chromium alloy (positive pole) - nickel-silicon alloy (negative pole) conductor crosslinked polyolefin insulated copper wire braid total shield thermoplastic sheath low smoke
HBKXEYGP Ii-grade nickel-chromium alloy (positive pole) - nickel-silicon alloy (negative pole) conductor ethylene - propylene insulated copper wire braid total shield thermoplastic sheath low smoke free halogen resistance for nuclear power plant
HBKCBYJYGP Ii-grade copper (positive pole) - copper-nickel alloy (negative pole) conductor crosslinked polyolefin insulated copper wire braid total shield thermoplastic sheath low smoke halogen free
HBKCBEYGP Ii-grade copper (positive pole) - copper-nickel alloy (negative pole) conductor ethylene - propylene insulated copper wire braid total shielding thermoplastic sheath low smoke halogen-free flame retardant thermocouple for nuclear power plant

 