  • 7(1).jpg

WR3 Fs a 2 05 3 x6 three-core 16 mm fluoroplastic insulated wire armored well heating cable

use  Theproductismainlyusedtoimprovetheflowperformanceofcrudeoilandtherecoveryefficiencyofheavyoil.  Themainparameters  (l)geometricdimensions  Outerdiameterofcablesheath:15.7mm  Outsidediameterofstee

Classification:

Oilfield special cable


Description

use

  The product is mainly used to improve the flow performance of crude oil and the recovery efficiency of heavy oil.

  The main parameters

  (l) geometric dimensions

  Outer diameter of cable sheath :15.7mm

  Outside diameter of steel core :3.0mm

  Minimum diameter of pulley: greater than or equal to 480mrn

  Conductor cut and product :6mm squared

  (2) electrical properties

  Maximum test voltage :2500V DC 5min

  Maximum working voltage :1000V

  The minimum insulation resistance: 500 m or more Ω. Km

  Conductor dc resistance: 2.88 or less Ω/km

  (3) mechanical properties

  Cable damage :106kN

  Cable weight :839kg/km

  Recommended working tension :50kN

  (4) cable operation

  Long-term working temperature: 205 ℃, short-term use temperature 232 ℃.

Cable structure