WR3 Fs a 20 5 3 x 16 three-core 20mm fluorine-plastic insulated wire armored well heating cable
use Thisproductismainlyusedforoilwellheating,viscosityreductionandparaffinremoval.Improvecrudeoilflowperformanceandenhanceheavyoilrecoveryefficiency. Themainparameters (l)geometricdimensions Outer
Classification:
Oilfield special cable
Description
use
This product is mainly used for oil well heating, viscosity reduction and paraffin removal. Improve crude oil flow performance and enhance heavy oil recovery efficiency.
The main parameters
(l) geometric dimensions
Outer diameter of cable sheath :20mm
Outside diameter of steel core :5.0mm
Minimum diameter of pulley: greater than or equal to 510mrn
Conductor cut and product :16mm squared
(2) electrical properties
Maximum test voltage :2500V DC 5min
Maximum working voltage :1000V
The minimum insulation resistance: 500 m or more Ω. Km
Conductor dc resistance: 1.08 or less Ω/km
(3) mechanical properties
Cable damage :150kN
Cable weight :1414kg/km
Recommended working tension :70kN
(4) cable operation
Long-term working temperature: 205 ℃, short-term use temperature 232 ℃.