  • 7(12).jpg

Major loop power cable used for frequency converter

Productcharacteristicsandapplication Gableismainlyusedforconnectionofvariablefrequencypowersupplyandfrequencyconversionelectricmachine,andpowertransmissionanddistributionlineswithratedvoltageof1kVandt

Classification:

Power cable


Description

Product characteristics and application

 Gable is mainly used for connection of variable frequency power supply and frequency conversion electric machine,and power transmission and distribution lines with rated voltage of 1 kV and the below, for the use of power transmission,and is specially applicable to paper-making, metallurgy, chemical industry, petroleum, power generation, metal processing,mining, railway and food processing and other industries.

 

Executive Standards

Enterprise standard

 

Application characteristics

1 .The rated voltage of U0/U is divided into 0.6/1 kV.
2. The maximum long term admissible working temperature of cable conductor is 90℃.
3. The maximum temperature of cable conductor in short circuit (not more than 5s at longest duration) shall not exceed 250℃.
4. Ambient temperature for cable laying shall not be lower than 0℃.
5. Minimum bending radius shall not be less than 15 times of outer diameter of cable.
6. It has a strong property of withstand voltage impact and can withstand impulse voltage while high speedy and frequent frequency conversion.
7. It has a good shielding property and can reduce adverse effects of higher harmonic wave while frequency converter output.
8. The DC resistance of conductor is consistent with the requirements of GB3956 standard.
9. It can undergo 3.5kV/5min power frequency withstand voltage test without breakdown.
10. Inflaming retarding cable can undergo burning test of beam forming specified in GB12666.5.
11.Low smoke halogen-free inflaming retarding cable can undergo burning test of beam forming specified in GB12666.5, moreover smoke density while burning consistent with the requirements of GB12666.7 (IEC1034), pH value of gas aqueous solution while burning shall be 4.3 or above, electric conductivity shall be 10 u s/mm or below, moreover consistent with the requirements of IEC754-2.

 

Structure of Cable

 

Product model specifications

Type

Name

No.of cores

主线芯标称截面

接地线芯标称截面

BPYJVP

Major loop cable used for cross-linked polyethylene insulated PVC sheathed copper wire weave shielded frequency converter

3

4.0~240mm²

1.0~50mm²

BPYJVP1

Major loop cable used for cross-linked polyethylene insulated PVC sheathed copper wire winding shielded frequency converter

BPYJVP1-2

Major loop cable used for cross-linked polyethylene insulated PVC sheathed copper wirewinding copper tape wrapping doubleshieldedfrequency converter

BPYJVP3

Major loop cable used for cross-linked polyethylene insulated PVC sheathed aluminum (aluminum-plastic) tape shieldedfrequencyconverter

BPYJVPP2

Copper core cross-linked polyethylene insulated PVC sheathed copper wire weave and copper tapecombination shieldedfrequency conversion cable

BPGGP

Copper core silicon rubber insulated copper wire weave shielded frequency conversion cable

BPGGP2

C-opper core silicon rubber insulated sheathed copper tape shielded frequency conversion cable

BPGGPP2

Copper core silicon rubber insulated copper wire weave and copper tape combination shielded frequency conversion cable

BPGVFP

Copper core silicon rubber insulated Ibutyronitrile composite sheathed copper wire weave shielded frequency conversion cable

BPGVFP2

Copper core silicon rubber insulated butyronitrile composite sheathed copper tape shielded frequency conversion cable

BPGVFPP2

Copper core silicon rubber insulated butyronitrile composite sheathed copper wire weave and copper tape combination shieldedfrequency conversioncable

BPVVP

Copper core PVC insulated PVC sheathed copper wire weave shielded frequency conversion cable

BPVVP2

Copper core PVC insulated PVC sheathed copper tape shielded frequency conversion cable

BPVVPP2

Copper core PVC insulated PVC sheathed copper wire weave and copper tape combination shielded frequency conversion cable

ZR-BPYJVP

Major loop cable used for cross-linked polyethylene insulated PVC sheathed copper wireweave shielded inflaming retardingfrequencyconverter

ZR-BPYJVP1

Major loop cable used for cross-linked polyethylene insulated PVC sheathed copper wire winding shielded inflaming retardingfrequencyconverter

ZR-BPYJVP1-2

Major loop cable used for cross-linked polyethylene insulated PVC sheathed copper wire winding copper tape wrapping double
shielded inflaming retarding frequency converter

ZR-BPYJVP3

Major loop cable used for cross-linked polyethylene insulated PVC sheathed (aluminum-plastic) tape shielded inflaming
retardina freeuencv converter

WDZ-BPYJEP

Major loop cable used for cross-linked polyethylene insulated polyolefin sheathed copper tape sh一elded low smoke halogen-
free inflaming retarding frequency converter

WDZ-BPYJEP2

Major loop cable used for cross-linked polyethylene insulated polyolefin sheathed copper tape sh一elded low smoke halogen-
free inflaming retarding frequency converter

WDZ-BPYJEP1

polyethylene insulated polyolefin sheathed copper wire winding shielded low smoke halogen-free inflaming retarding frequencyconverter

WDZ-BPYJEP1-2

Major loop cable used for cross-linked polyethylene insulated polyolef in sheathed copper wire winding copper tape wrapping
double shielded low smoke halogen-free inflamingretarding frequency converter

WDZ-BPYJEP3

lyethylene insulated polyolefin sheathed aluminum (aluminum-plastic) tape shielded low smoke halogen-free inflaming
ardina freauencv converter

 