Mining XLPE Insulated Power Cable at Rated Voltage up to and Include 8.7/10Kv
Productcharacteristicsandapplication MiningXLPEinsulatedcablesareusedforfixedlayingunderwelloruppergroundwithA.C50HzandthepowertransmissionintransmissionanddistributionpowerlinesatratedvoltageUO/Uupt
Classification:
Mining cable
Description
Product characteristics and application
Mining XLPE insulated cables are used for fixed laying under well or upper ground with A.C 50Hz and the power transmission in transmission and distribution power lines at rated voltage UO/U up to and include 8.7/10kV. The products have characters as large transmission capacity, high operating temperature, better electrical performance, better flame-retardant performance and readily to be installed etc.
The MYJV cables can be installed under well, in tubes and ducts but could not bear outside force.
The MYJV22 cables could be installed under well, in tubes, ducts and soil and could bear mechanical outside force but could not bear large pulling force.
The MYJV32 cables could be installed under well, in tubes and ducts and can bear mechanical outside force and relative pulling force as well.
The MYJV42 cables could be installed under well, in tubes and ducts and can bear mechanical outside force and larger pulling force as well.
Executive Standards
MT 818
MT 386
GB 3953
G B 3956
Operating characteristics
Operating Features
The power frequency rated voltage UOIU: 0.6/1 kV, 1.8/3kV, 3.6/6kV, 6/6kV, 6/10kV, 8.7门0kV
The max. permissible operating temperature of cable conductor: 90℃
The max. temperature of cable conductor shall not be more than 250`b when short circuit(the max. duration shall not be more than 5s)
Bending radius of cable: D≤15
The ambient temperature when laying≥O℃(if it has to be laid at the ambient temperature below 0℃, the cable shall be pre-heated upper 0G and then be installed)
Construction of Cable


Type and names
|
Type |
Description |
Number of cores |
Nominal cross-Sectional area |
|
|
Power wire |
Ground wire |
|||
|
MYJV |
The mining XLPE insulated PVC sheathed power cable |
3 |
0 |
1.5~300mm² |
|
MYJV22 |
The mining XLPE insulated steel tape armored PVC sheathed power cable |
|||
|
MYJV32 |
The mining XLPE insulated fine steel wire armored PVC sheathed power cable |
|||
|
MYJV42 |
The mining XLPE insulated coarse steel wire armored PVC sheathed power cable |
|||