  • 1(24).jpg

Rated voltage 10kV, 35kV overhead insulated cable

ScopeofapplicationThisproductisanewsystemproductoftheoverheadpowerline,thepowergridconstructionandtransformationof10kVand35kVpowerlinesshouldbepreferred.Itisthelinemaintenanceandsafetyofthemostsuitabl

Classification:

Overhead insulated cable


Description

Scope of application
This product is a new system product of the overhead power line, the power grid construction and transformation of 10kV and 35kV power lines should be preferred. It is the line maintenance and safety of the most suitable series of products. Soft copper core products are suitable for transformer lead off line and so on.
 
Conditions of use
(1) rated voltage is 10kV and 35kV.
(2) the cable temperature under installation should not below 20 ℃.
(3) when the short circuit (the longest duration of no more than 5 s) the highest degrees: cable with cross-linked polyethylene insulation at 250 ℃; High density polyethylene insulation is
150 ℃.
(4) maximum allowable working M degree of the cable conductor: there are loadline structure cables, which are determined by the maximum allowable working temperature of the insulation for a long time. Crosslinked poly (ethyl
PVC insulated 90 ℃; High density polyethylene insulation is 150 ℃.
(5) allowable bending radius of the cable: shall not be less than the diameter of the cylinder during the cable bending test.
 
Model and name

model

The name of the

Lay out precautions

some

Nominal cross section

10KV

35KV

JKYJ

  Copper core crosslinked polyethylene insulated overhead cable

 Overhead fixed installation, soft copper core production pinchuan in transformer lead down line cable timing, the cable and trees should be considered to maintain a certain distance.

1

10~300mm²

50~300mm²

JKTRYJ

  Flexible copper core crosslinked polyethylene insulated overhead cable

3

25~300mm²

JKLYJ

  Aluminum core crosslinked polyethylene insulated overhead cable

3+K(A)或3+K(B)

25~300mm²

JKLHYJ

  Aluminum alloy core crosslinked polyethylene insulated overhead cable

其中In whichK25~120mm²

JKY

  Copper core polyethylene insulated overhead cable

1

10~300mm²

JKTRY

  Flexible copper - core polyethylene insulated overhead cable

JKLY

  Aluminum core polyethylene insulated overhead cable

JKLHY

  Aluminum alloy core crosslinked polyethylene insulated overhead cable

JKLYJ/B

  Aluminium core natural color crosslinked polyethylene insulated overhead cable

 Overhead fixed cable erection

 
The cable should be considered to keep a certain distance from the tree.

3

25~300mm²

JKLHYJ/B

  Aluminium alloy core natural color crosslinked polyethylene insulated overhead cable

3+K(A)或3+K(B)

25~300mm²其中In whichK25~120mm²

JKLYJ/Q

  Aluminum core lightweight crosslinked polyethylene insulated overhead cable

 When laying overhead fixed cable, the cable and tree should be kept at a certain distance. When the cable is running, only short contact between the cable and the tree is allowed.

1

10~300mm²

JKLHYJ/Q

  Aluminum alloy core light crosslinked polyethylene insulated overhead cable

JKLY/Q

  Aluminum core lightweight polyethylene insulated overhead cable

JKLHY/Q

  Aluminium alloy core light polyethylene insulated overhead cable

JKLGYJ

  Aluminum core lightweight polyethylene insulated overhead cable

 

online message

Security verification
Confirm
%{tishi_zhanwei}%